Connects2 IGNI-GEN - £24.99 inc VAT
Connects IGNI-GEN - Universal CAN-BUS Ignition Feed Generator for fitting aftermarket Head Units and Handsfree Kits
IGNI-GEN will switch on the ignition output if it detects that the engine has been running for a few seconds. It will switch off again a few seconds after the engine stops. The exact timing will vary dependant on the vehicle's electrical system. The learning process only needs to be carried out once at the time of installation as the unit stores a permanent record of the information it aquires. The information is still retained ecen if the unit is disconnected from the battery. The unit will only need to be reprogrammed if changes are made to the electrical system of the vehicle, such as changing the alternator or the battery.
Step 1
Make the following connections:
Black - Ground
Yellow - Permanent 12V
Red - Ignition Output to external device
Step 2
Start the engine of the vehicle
Step 3
Disconnect the programming bullets and reconnect them again. Note the time (this starts the learning process, the ignition wire will turn on during this time)
Step 4
After 1 minute from initiating the learning process (step 3) turn off the engine
Step 5
Wait until the ignition output turns off (Around 40 seconds)
The ignition output is rated at 300mA
|